Thursday, March 15, 2018

Noisy Neighbors


Originally appeared in the AIA Design for Aging Newsletter in August 2014.

Moving is always stressful.  You have to find enough boxes to hold all your stuff.  You have to have utilities shut off in one place and turned on in another, hopefully at the appropriate times.  You need a van and a lot of friends who will move you for pizza and beer or soda.


Moving into a retirement community is stressful too, although hopefully you can afford professional movers at this point in your life.  However there are a lot of adjustments to be made.  For one, most of the residents moving in will be leaving a single family home and are accustomed to the buffer they have between their house and any neighbors.  This is not the case in most residential accommodations in a CCRC.  In most instances, at best, you will have one neighbor directly on the other side of the wall from you.  In many cases, you will have neighbors to both sides, plus above and below.

Sales people will likely not understand and thus not explain to residents the reality about what they may expect to hear from their neighbors.  And this is a disservice to the residents and to the administrators who will hear the complaints.  But expectations need to be managed in order to not to disappoint new move-ins.  The walls, ceilings and floors between units will in most cases never be “sound proofed”, but we as designers will do what is possible to manage and dissipate sound to acceptable levels.


I grew up in a semi-detached home until I was 15 and then lived in a townhouse with my family or the college dorms until I was 27, when I bought a single family home with my wife.  You could say I was used to having neighbors.  For almost 30 years I expected to hear my neighbors come in the door, hear their garbage disposal and generally, hear a bit of their everyday life.  But as long as the neighbors kept their AC/DC album to a normal level, this was ok because this is what I had come to expect.  However, this is not what many incoming residents to retirement living may expect.  They may expect the same quite environment they have now in a single family home.  They have no children.  They may even live completely alone.  The only sound they may hear is made directly by themselves personally.
When Aerosmith is your neighbor...you're going to hear something.

None of the close quarter living units I experienced growing up were even close to complying with ‘modern’ sound requirements.  Current building codes address both air-borne sound and structure-borne sound.  Simply stated air-borne sound is hearing your neighbor’s voice or TV.  Structure-borne noise is hearing your neighbor’s footfalls above you or their garage door open.  So as a minimum the wall, floor and ceiling assemblies between dwelling units must meet and sound transmission class of 50.  This far exceeds standard wall construction found in older building stock or in a single family home.  A wood stud wall with a layer of wall board on either side has an STC of about 34.  To get to about 50-54 STC (as measured in a laboratory) a wood stud wall must have 2 layers of wall board on one side of the studs, the stud cavity is filled with fiberglass insulation,  with another layer fastened resilient metal clips which offset the board from the stud by ½ inch.  These clips allow one side of the wall to vibrate independently from the other side and as such the noise does not translate from one side of the clip to the other at 100%.  The fiberglass insulation works as an attenuator, reducing the strength of the signal, so to speak.  This wall is also in effect 50% more dense than the standard wall.  The building codes also require that all openings, cracks and seems must be sealed with acoustical caulk and that penetrations, such as electrical outlets, must be staggered between studs, so that there aren’t one in each side within the same cavity opening.

Also, from the laboratory to the field conditions of the actual building, the STC is expected to be reduced by 5 levels.  This is most likely due to imperfect conditions and inherent weak points in corners and along edges, as well as penetrations needed.  So while we design to meet an STC of 50 in our drawings and the code plan reviewers see this, it is expected that a field test on the same assembly would provide a result of 45 and this still meets code.  Sound will penetrate a system at the weakest point, so anywhere the defenses are down such as at a door or an electrical box, that is where the sound will transmit.  Unfortunately, if the rest of the room is treated well acoustically, it doesn’t really offset a break in the assembly, like a hole or seam that is unsealed.  It only takes a small hole in a rubber raft to sink it.

So in a sense, a standard party wall is about 15 to 20 STC points higher than it would have been prior to the regulations in the building codes.  That seems pretty good, but is it?  Consider these facts.  A rule of thumb is for every 10 STC you add to an assembly, the sound coming to the other side is roughly half as loud.  In diminishing returns, 5 STC is clearly noticeable, 3 STC is just barely perceptible, and 1 STC is almost imperceptible.  Mass is important to acoustical performance.  If you double the thickness of a membrane, such as 2 layers of wall board in lieu of one, the STC rating will increase by about 5, which is clearly noticeable.  Installing insulation is a wall also adds about 5 to the STC.
Example of an STC 30 wall - Photo Credit:  Gypsum Association

Walls assemblies with STC values far exceeding the code are often called a “luxury” and as such they come with a price.  A wall with an STC of 60 will pretty much eliminate the perception of loud speech from one side of the wall to another.  A double wall certainly improves STC ratings.  But they take up a lot of square footage (which often can’t be factored into rentable space) and they are more costly to build.  Also masonry walls are very dense and as such very good insulators of sound, but again come at a cost.  A 10 inch hollow block wall by itself attains nearly a 50 STC. 
Example of a 55-59 STC Wall - Photo Credit:  Gypsum Association
Floors will be very similar to walls, except a typical assembly “sandwich” would be made up of wood joists and fiberglass insulation topped with plywood subfloor and gypsum poured topping.  The bottom would have several layers of wall board attached to the same kind of metal clips on the underside of the joists.  Additionally, a floor needs to perform in terms of impact noise, i.e. footfalls, which is a structure-borne noise.  Typically this is addressed additionally with an acoustical mat placed between the gypsum topping and the plywood in the assembly.  These mats provide additional mass as well as resilience to the floor make up.  The mats can also be placed right below flooring as well.
Example of an STC 37 Floor - Photo Credit:  National Gypsum

Example of an STC 60 Floor - Photo Credit:  National Gypsum

STC ratings are a fairly sensible predictor of how a wall will perform.  However, SCT uses a range of 125 to 4000 Hertz, which are the range of frequencies associated with human speech.  This range does not really consider very high or very low frequencies, such as those produced by machines, air handlers or electrical transformers.  It isn’t perfect but the STC rating system is the standard by which designers live by.

I am using examples above in terms of wood construction because that is fairly standard in low to mid-rise residential construction.  But actually metal studs preform a bit better than wood studs.  This is due to their flexibility characteristics as they a can soften or decouple some of the noise vibrations from one side of the wall to another. In terms of the big three in acoustical dissipation, there is Mass, Airspace between and Resiliency (or materials that flex and decouple).  Any time you can add two or more of these properties to an assembly, improvements will be realized. 

During the pricing exercises on building or renovation project, we as designers are often asked to make concessions to reduce costs.  Many of these decisions, which the Owner must be a part of, may affect acoustical comfort.  These items include replacing cast iron waste pipes for PVC pipes, reducing or changing types of insulation on pipes, providing alternate wall assemblies (here we can point to code now to limit this reductions), alternate finishes which may be less absorptive of sound, alternate HVAC and mechanical items that may perform worse acoustically or alternative door hardware.  All of these issues can degrade the acoustical comfort in a building versus the initial design, so be careful.

How does this all translate to the expectations of future residents?  When discussing their future neighbors, the sales team must not convince the clients they won't hear anything their neighbor does.  It is expected in new construction that dwelling units will not be sound proofed, but that sound will be reduced to an accepted standard.  They are likely moving into new type of housing product whether it be apartment or semi-detached home, so it must be explained that there is an inherent difference between living on your own plot versus living in a community.  The sales team should learn, with the help of their design professionals, how a standard house wall performs next to the proposed party walls in the housing product.  How do they relate in terms of STC to each other and to the minimums mandated by code?  If the product is new, a pricing alternate could be explored for “luxury” STC 60 walls.  It could be an option to residents to buy up to this option.  But this is a very difficult feature to add later.

I’ve always found it interesting that in aging, it is often said the hearing goes first, yet in many cases the resident population we serve seem to be ultra-sensitive to sounds in their new homes.  I believe much of this is the result of expectations.  People coming to live in an apartment after having lived on their own plot for 30 or 40 years tend not to expect to hear their neighbors at all.  They don’t have common walls or hallways.  They don’t have elevators nearby.  They may be on the same routine as their spouse and don’t worry about someone being a night owl while the other is an early bird.  Let’s face it, if they’ve lived with another person for 40 year, they probably have adjusted to their routine.  A new neighbor is a completely different story.  They are probably used to the noises of their old HVAC system, but their new one may make different sounds.  Not more noise, just different.

Monday, March 6, 2017

House or Home?

The bulk of my architectural career has and is spent designing structures that are not considered Residential per the building codes.  Some may call it Commercial.  Much of it is Institutional by Code.  But that does not mean it is not someone’s Home.  You see, I primarily design buildings in the Senior Living sector; have been my entire career.

When I began my career more than 20 years ago, there was already a movement under way to make retirement and senior living spaces much more residential.  Even in dwellings classified as Skilled Nursing Facilities, the idea that these building should feel like someone’s home had been one that many providers had embraced.  The problem was that most of the providers (at that time) had buildings that looked like hospitals instead of your home. 
A Cruciform Church.  Early hospitals took their shapes from churches.  Thus, so did the early nursing home.

Beddington Corner Hospital. (source: historic-hospitals.com )
The economy is easy to see.  The result is not necessarily a religious experience.

What can you do for an existing building?

I feel the best way to illustrate how our buildings fulfill the qualifications of "home" is by showing how we can improve existing condtions.  The difficulty lies in all of the regulations associated with a facility that provides nursing care to its residents.  The International Building Code identifies these buildings as an Institutional or I-2 building.  NFPA reviews these buildings in (almost) exactly the same way as a hospital (Health Care).  In either case, the Use Group enclosed therein is the second most hazardous category according to code.  What would be worse in terms of hazard?  Think fireworks factory.  The hazard to Skilled Nursing Facilities is exiting…someone bed or chair bound is not able to get out on their own; or not capable of self-preservation in CodeSpeak.  Also in Institutional buildings, nearly all aspects of the building have to be accessible.  So features required in these buildings are not similar to those you have in your home, nor in a building pre-1990.


So what can we do?

Sometimes an improvement to the exterior facade can make a significant impact with easier application as it is, more or less, surface applied.  However, most Institutional buildings are non-combustible construction, so there are limits.  You can’t just add anything to the exteriors.  In new construction, you can utilize scale and materials to humanize the sequential experience.  Many vintage Skilled Nursing Facilities are economic 'blocks'.  Even modest additions to the exterior may improve the approach to a building.  

Mennonite Home Exterior - Before
Mennonite Home Exterior - After (Obviously).  The addition to the right created a one-story, human scale.

But let’s face it, the folks who reside in these buildings spend nearly 100% of their time inside.

What about the interiors?

In new buildings, it is much easier to provide open, residentially scaled rooms on the interior with connections to the outside.  In the many, many renovation projects of nursing homes we have done, it is much more of a challenge.  Traditionally. resident rooms line up in a continuous 8-foot wide corridor up to 120 feet from the original nurse’s station.  One way to bring some residential life to these facilities is to blow out a couple of rooms to allow the addition of a living room with access to windows.  Many of these buildings are non-combustible, as I said earlier, so exterior and corridor walls are often concrete block and they do not have tall ceilings.  You can see the challenges.

Corridor - Before.  Hard and highly reflective surfaces are not atypical in vintage nursing homes.
Corridor Concept Sketch 
Corridor  - After.  Sometimes all you have to work with are finishes and lighting.
Another issue is that whether there are 15 or 50 residents, they all need to eat in a dining room.  No one has a dining room with seating for 50 (well, no one that invites me over for dinner anyway).  These rooms need to be broken up visually into human scaled rooms.  Some times that means providing a serving (residential looking) kitchen with several smaller rooms around it for dining.

Dining Room - Before.  No connection to the outside or the community at large.
Dining Room - After.  Here we had the opportunity to add skylights to add natural daylight.
Adding just a bit of privacy and homelike environments can also do wonders for one's main living area.  This is especially true in a double occupancy room.

A Double Room - Before.  Only the thin curtain between you and a neighbor.
A Double Room - After.  There is still a curtain, but the interior window provides a more substantial barrier.
FYI: the window wall is not a full height wall so as to not trigger sprinkler revisions.

There has been a more recent movement for skilled nursing called the Green House Project © about 10 years ago.  And while the word “house” is in the name, the feeling of “home” is what is intended.  This method limits the occupant count to 10, favors a universal worker for more homelike care, and has strict spatial rules.  This project is an actual Brand-name developed by a doctor and requires a lot of staff training.  The concept has a lot of merit and you can learn a lot more about it on their website here:   The Green House Project

It turns out that concepts we (not just my firm but others, too) had in the 1990’s have only just made it to the Code books.  In 2012, the NFPA 101 Life Safety Code addressed the ability to allow a kitchen to be open to the corridor (with a whole lot of provisions).  Nearly the same provisions made it to the 2015 IBC.  In fact, the Commentary shows a floor plan illustrating the open kitchen concept with a plan by our office in 1995.  For twenty years, we had to convince State and Local jurisdictions that it should be allowed, so that is a little sweet reward to be the example in the Code Book!
ICC used this 20 year old project of RLPS' to illustrate a brand new concept in the 2015 IBC.

While many may not consider what our office does as "residential", I would argue that it is extremely important to our end users in the buildings we design that the spaces, "Look like, act like, feel like home."  This quote is attributed to one of our clients, who had the vision to create the first freestanding Hospice facility in Pennsylvania.  That's another topic in itself.

This post is part of the ArchiTalks series (led by Bob Borson of Life of an Architect ) where a group of us (architects who also blog) all post on the same day and promote each other’s blogs. This month’s theme is led by Keith Palma and is "House or Home".  A lot of other talented writers who also are architects are listed below and are worth checking out:


Bob Borson - Life of An Architect (@bobborson)
The Designation between House and Home
-->Lora Teagarden - L² Design, LLC (@L2DesignLLC)
House or Home? It's in the story.

-->Collier Ward - One More Story (@BuildingContent)
House or Home? A Choice of Terms

-->Jeremiah Russell, AIA - ROGUE Architecture (@rogue_architect)
house or home: #architalks

-->Eric T. Faulkner - Rock Talk (@wishingrockhome)
House or Home -- Discover the Difference

-->Michele Grace Hottel - Michele Grace Hottel, Architect (@mghottel)
"house" or "home"?

-->Meghana Joshi - IRA Consultants, LLC (@MeghanaIRA)
Architalks #24 : House or Home

-->Brian Paletz - The Emerging Architect (@bpaletz)
House or Home? - Depends

-->Michael LaValley - Evolving Architect (@archivalley)
House or Home? Train for One, Design for Another

-->Greg Croft - Sage Leaf Group (@croft_gregory)
House or Home

-->Jeffrey Pelletier - Board & Vellum (@boardandvellum)
Designing a House into a Home

-->Kyu Young Kim - J&K Atelier (@sokokyu)
Making a House a Home

-->Keith Palma - Architect's Trace (@cogitatedesign)
I don't design homes

-->Mark Stephens - Mark Stephens Architects (@architectmark)
#ArchiTalks #24 House or Home? #RefugeeCrisis @GrainneHassett mentioned

-->Jarod Hall - di'velept (@divelept)
A Rose by Any Other Name...

-->Mark R. LePage - EntreArchitect (@EntreArchitect)
Emotional Marketing for Architects: House or Home?

-->Marica McKeel - Studio MM (@ArchitectMM)
ArchiTalks: House or Home?

-->Jeff Echols - Architect Of The Internet (@Jeff_Echols)
House or Home? The Answer to Everything

-->Jarod Hall - di'velept (@divelept)
A Rose by Any Other Name...

-->Samantha R. Markham - The Aspiring Architect (@TheAspiringArch)
6 Ways to Make your Architecture Studio feel like Home

-->Nisha Kandiah - ArchiDragon (@ArchiDragon)
Dwelling on a Macro scale

-->Tim Ung - Journey of an Architect (@timothy_ung)
Architalks - A House is not a home

-->Rusty Long - Rusty Long, Architect (@rustylong)
House or Home